COMPARISON SHEET BETWEEN ALL MODELS OF ANALAB MULTIPARAMETER ANALYZER
Specification |
µMultiCal10 |
µMultiCal50 |
µMultiCal100 |
µMultiCalHandhled |
|
pH Range |
-2.000 to 20.000 |
-1.00 to 15.00 pH |
|||
pH Resolution |
0.1 / 0.01 / 0.001 |
0.01 pH |
|||
Relative Accuracy |
±0.02 / 0.002 pH |
± 0.02 pH |
|||
mV / ORP Range |
± 2000.0 mV |
||||
ORP |
Yes |
||||
Resolution (mV) |
0.1 |
||||
Relative Accuracy |
± 0.2 mV OR 0.05%, whichever is greater |
||||
Slope |
80-120 % |
80-120 % / 90-110% |
80-120 % / 90-110% / User Adjustable |
80-120 % |
|
Total Numbers of Slopes |
02 for Three Point & 01 for Two Point Calibration |
04 for Five Point & 02 for Three Point Calibration |
04 for Five Point & 02 for Three Point Calibration (Max.10 slops depend on calibration point selection) |
01 |
|
Auto Buffer Recognition @25⁰C |
4.01, 6.86 / 7.00, 9.18 / 10.01 for Three-point Cal. 6.86 / 7.00, 4.01 / 9.18 / 10.01 for Two -point Cal. |
4.01, 6.86 / 7.00, 9.18 / 10.01 for Three-point Cal. Add.1.68, & 12.45 for Five-point Calibration |
4.01, 6.86 / 7.00, 9.18 / 10.01 for Three-point Cal. Add.1.68, & 12.45 for Five-point Cal.& 10 Buffers for Multipoint |
7.00, 4.01 / 9.18 |
|
Buffer Standard |
US / NIST / EURO |
US / NIST / EURO / DIN |
US / NIST & EURO |
||
pH Result |
Manual |
Auto / Manual |
Manual |
||
Calibration Reminder Alarm |
0 – 99 hrs. |
No |
|||
Short link |
Provided |
||||
Conductivity Range |
0.1 to 2000 mS/cm. (Distributed in Six Range) |
0.1 to 200 mS/cm. |
|||
Resolution |
0.001,0.01,0.1 µS/cm & 0.001, 0.01, 0.1, 1 mS/cm |
0.001,0.01,0.1 µS/cm & 0.001, 0.01 mS/cm |
|||
TDS Range |
0.1 to 1000000 ppm |
0.1 to 100000 ppm |
|||
TDS Resolution |
0.001, 0.01, 0.1 ppm & 0.001, 0.01, 0.1 ppt |
0.001, 0.01, 0.1 ppm & 0.001, 0.01 ppt |
|||
Resistivity Range |
NA |
20.00 MΩ to 50.00 KΩ, 5.00 KΩ, 500.00 Ω, 50.00 Ω, 0.50 Ω |
NA |
||
Resistivity Resolution |
NA |
0.001, 0.01, 0.1 KΩ & 0.001,0.01,0.1 MΩ |
NA |
||
Salinity |
NA |
0.01 to 80000.0 ppm NaCl |
NA |
||
Number of Range |
Six |
Six |
Six |
One |
|
Calibration Standard |
Six Conductivity & TDS Standard - One Per Range |
One |
|||
Calibration Factor |
Six – One Per Range |
One |
|||
Range Selection |
Auto / Manual |
Manual |
|||
Suitable Cell Constant (K) |
0.1,0.5 & 1.0 |
1.0 |
|||
Adjustable Cell Constant |
0.09 to 0.11 K, 0.45 to 0.55 K & 0.90 to 1.1 K |
0.90 to 1.1 K |
|||
Conductivity to TDS Conversion |
0.40000 to 1.00000 (Adjustable Factor) |
0.40000 to 1.00000 (Adjustable Factor) |
|||
Temperature Coefficient |
0-10.000 % per ⁰C (Adjustable) – One Per Range (total Six) |
0-10.000 % per ⁰C (Adjustable) |
|||
Conductivity Display |
@ Actual temperature and @ 25⁰C, TDS, |
@ Actual temperature and @ 25⁰C, TDS, Resistivity & Salinity |
@ Actual temperature and @ 25⁰C, TDS, |
||
Temperature Range |
-5.0 to 130.0⁰C |
0.0 to 130.0⁰C |
|||
Resolution |
0.1⁰C |
||||
Relative Accuracy |
± 0.1⁰C |
||||
Temperature Compensation |
Auto / Manual |
||||
Temperature Calibration |
Built in Facility |
||||
Error Indication |
For pH = “Bad Buffer / Electrode,” In-complete calibration, Calibration Due, pH overrange For Conductivity= Wrong Standard / Cell”, “Cell Short”, “Try Upper Range”, “Try Lower Range”, Common = “Temperature probe Error” “Low Memory |
For pH = “Bad Buffer / Electrode,” In-complete calibration, pH overrange For Conductivity = Wrong Standard / Cell”, “Cell Short”, “Try Upper Range”, “Try Lower Range”, Common = “Temperature probe Error” “Low Battery” |
|||
Display |
16 x 2 Line Alphanumeric Backlit LCD |
20 x 4 Line Alphanumeric Backlit LCD |
16 x 2 Line Alphanumeric Backlit LCD |
||
Keyboard |
Membrane waterproof polyester soft complianceto UL/ROHS |
||||
Calibration Data Storage |
Last data – In Nonvolatile memory |
No |
|||
Analysis Data Storage |
< 500 |
< 750 |
< 1000 |
No |
|
Data Search |
With Record No., and by scrolling |
With Record No., Batch No., specific date, date range and by scrolling |
NA |
||
Report Formation |
Non -GLP |
As per GLP |
No |
||
CFR Compliance |
No |
No |
Yes – In-built with the system |
No |
|
Password Protection |
No |
For Date & Time, Calibration Mode, Analysis Mode and for deletion of data |
For 40 users,10 Reviewers, 2 Admin & 1 Manufacture Diff ID and PW |
No |
|
Printer Interface |
Centronics Parallel Port and Serial (RS - 232C) Port |
No |
|||
Printer Selection |
40 / 80 column |
No |
|||
PC Connectivity |
No |
No |
USB Interface Cable with Driver with ANALABSAFE software |
No |
|
Power Supply |
DC adaptor run with 230 V AC |
Rechargeable Battery |
|||
IQ/OQ/PQ Documentation |
Yes - optionally |
||||
Calibration Certificate with traceability |
Yes - optionally |