Microcontroller Based Karl Fischer Titrator

Model : µAquaCal10+ | Make : ANALAB | HSN Code : 90278990

Supplied with 250ml Reaction Vessel, Dual Platinum Combined Electrode, Teflon Paddle, Teflon Assembly, Moisture Trap (02 Nos.), 250ml Amber Reservoir Bottle, Dispensing Tube (02 Nos.), Micro tip (02 Nos.) Teflon Tube for Dispensing Path, Power Cord, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

Technical Specification

  • Method of Detection : Conductometric / Volumetric
  • Range of Moisture Detection : Better than 100 ppm to 100% (depends upon type of sample)
  • Dispensing Resolution : 0.01ml
  • Magnetic Stirrer : Built-in with soft touch Key speed controller
  • Auto Neutralization : On / Off - users selectable - reduces the time between analysis & gives accurate results
  • Stirring Time : 00:00 to 99:00 (mm:ss) – users adjustable
  • End Point Sensitivity : 80-100 - users adjustable
  • End Point Time : 1-20 seconds - users adjustable
  • End Point mV : 1000-3000 mV - users adjustable
  • End Point Detection : By Audio & Visual Alarm
  • Over titration Alarm : Audio / Visual Alarm at 15 ml to save KF Reagent
  • Display of Reading : Moisture in ppm & percentage (%)
  • Auto Drain : For cleaning reaction vessel - useful for large & multiple volume sample
  • Flush : For cleaning dispensing path
  • Average KF Factor Calculation : Manual
  • Dispenser Calibration/Validation: Onsite by users
  • Dispenser MOC : SS-316L & Teflon for Corrosion Protection & Maintenance Free Operation
  • Dispenser Type : Motorized - For accurate measurement
  • Teflon Tube : To transfer KF reagent from KF reagent bottle to dispenser & dispenser to reaction vessel
  • Material of Construction : Epoxy Based Powder Coated Metallic Body / GMP Enclosure made up of Stainless Steel
  • Type of Electrode : Dual Platinum - Combined Type
  • Input : Electrode with Banana Connector
  • Error Messages : “Over KF” & “KF Factor Error” & ”Low Memory”
  • Short Link : Provided to diagnose the problem either with Instrument OR Electrode
  • Display : 16 x 2 Line Alphanumeric Backlit LCD
  • Keypad : Membrane waterproof polycarbonate soft touch keypad compliance to UL/ROHS
  • Analysis Data Storage : More than 500 analysis data which can be viewed & Print, company name, analysis date & time, record number, *Username, *Sample Name, *Bath Number/ID, sample type, sample volume (ml / mg), sample density (for liquid sample), stirring time, end point time, end point sensitivity, end point in ml, moisture result in % & ppm, instrument serial number, Instrument Make & Model & *Signature etc. Secondly, analysis data can be print online without saving analysis data in Instrument.
    (*: Not possible to enter data by instrument keypad but it will be handwritten)
  • Searching of data : With record number by scrolling.
  • Report Formation : As per Non-GLP Compliance
  • Printer Interface : Centronics Parallel Port / Serial (RS-232 C) Port
  • Printer : 40 / 80 Column Dot Matrix Printer (Printer must procure optionally)
  • Power Supply : 230 VAC ±10%, 50 Hz